Shanghai, China
300000
T/T, Western Union, Paypal
TRFK16
Insulating Paper
Active Type
Single Stage Type
Electromagnetic Type
TR
Standard Boxes
24*41*10
China
850450
Electronic, Lighting
Current Transformer
Single
Indoor
Protection, Measurement
Single Layer & Tightly Wound Type
FK Series open current transformers
FK Series
The FK Series of power transformers are equipped with an open core for easy installation on site .Through the principle of electromagnetic induction, the measured source is isolated from personnel and equipment ,effectively protecting personnel and property safety. The FK Series provides a variety of aperture and specifications to meet different use and installation requirements. At the same time ,we have a professional design team to accept customized products to meet all your needs.
Application:
Can be applied to engineering project transformation, rural power network transformation, power distribution , building energy consumption ,current detection , power monitoring ,energy consumption analysis .
For power harvesting ,
Metering loop electrical parameter acquisition.
Type | Ratio | Measuring | Protecting | Operatign Frequency(Hz) | |||
Rated input Primary Current (A) | Accuracy | Phase Linerity Error | Primary Current Max (A) | Accuracy | |||
FK-10 | 1000:1 | 5,10,20,32,50,75 | 0.5 | ≤30' | 300 | 5P | 50 |
FK-16 | 2000:1 | 50,100,150 | 0.5 | ≤30' | 1000 | 5P | 50 |
FK-24 | 2500:1 | 100,150,200,250 | 0.5 | ≤30' | 2000 | 5P | 50 |
FK-36 | 3000:1 | 200,300,400,500 | 0.5 | ≤30' | 4000 | 5P | 50 |
FK Series open current transformers
FK Series
The FK Series of power transformers are equipped with an open core for easy installation on site .Through the principle of electromagnetic induction, the measured source is isolated from personnel and equipment ,effectively protecting personnel and property safety. The FK Series provides a variety of aperture and specifications to meet different use and installation requirements. At the same time ,we have a professional design team to accept customized products to meet all your needs.
Application:
Can be applied to engineering project transformation, rural power network transformation, power distribution , building energy consumption ,current detection , power monitoring ,energy consumption analysis .
For power harvesting ,
Metering loop electrical parameter acquisition.
Type | Ratio | Measuring | Protecting | Operatign Frequency(Hz) | |||
Rated input Primary Current (A) | Accuracy | Phase Linerity Error | Primary Current Max (A) | Accuracy | |||
FK-10 | 1000:1 | 5,10,20,32,50,75 | 0.5 | ≤30' | 300 | 5P | 50 |
FK-16 | 2000:1 | 50,100,150 | 0.5 | ≤30' | 1000 | 5P | 50 |
FK-24 | 2500:1 | 100,150,200,250 | 0.5 | ≤30' | 2000 | 5P | 50 |
FK-36 | 3000:1 | 200,300,400,500 | 0.5 | ≤30' | 4000 | 5P | 50 |