Availability: | |
---|---|
3000000
T/T, Western Union, Paypal
1 Piece
Shanghai, China
Wide overload and excellent consistent ;
Different input current can be converted into a unified standard value ,which is convenient for signal acquisition;
The circuit is simple ,no external power supply is required and the operation is reliable .
Various installation methods, optional PCB installation and bolt fixing methods.
Various shape structures are available .
Widely used in AC motors ,air compressors, lighting ,heating ,ventilation and other devices in various places for current monitoring and protection ;power management ,automatic control systems for buildings ;
Electrical performance parameters | Operation temperature | -25℃~+55℃/-40℃~~+85℃ optional | Relative humidity | ≤90%hPa |
Internal insulation | Epoxy resin | Insulation resistance | >500 M Ohms/500Vdc | |
Medium strength | 2500Vac/min | Withstand impulse voltage | 5000V(1.2/50μsStandard Lightning Wave) | |
Operation frequency | 50~400Hz | Accuracy class | According to(IEC 61869-2 or (GB 20840.2-2014)accuracy 0.5,1.0 class | |
Environmental friendly | According to the requirement of RoHS | Certification | According to CE |
Type | L | W | H | H1 | A1 | A2 | A3 | ID | P |
TR0161B | 100 | 28 | 39 | / | / | / | / | 10 | 91 |
TR0159B | 120 | 50 | 56 | / | / | / | / | 20 | 106 |
TR0160B | 158 | 34 | 62 | 4 | 5.2 | 10 | 24 | 20 | 146 |
TR0180B | 196 | 38 | 74 | 5.5 | 6 | 12 | 29 | 30 | 182 |
TR0181B | 196 | 38 | 74 | 5.5 | 6 | 12 | 29 | 35 | 182 |
TR01123B | 50 | 90 | 110 | / | / | / | / | 18 | / |
TR0198-1B | 94 | 53 | 92 | / | / | / | / | 20 | 73 |
TR0199B | 111 | 79.5 | 99 | / | / | / | / | 30 | 90 |
TR01103B | 184 | 65 | 78 | / | / | / | / | 40 | 112 |
Wide overload and excellent consistent ;
Different input current can be converted into a unified standard value ,which is convenient for signal acquisition;
The circuit is simple ,no external power supply is required and the operation is reliable .
Various installation methods, optional PCB installation and bolt fixing methods.
Various shape structures are available .
Widely used in AC motors ,air compressors, lighting ,heating ,ventilation and other devices in various places for current monitoring and protection ;power management ,automatic control systems for buildings ;
Electrical performance parameters | Operation temperature | -25℃~+55℃/-40℃~~+85℃ optional | Relative humidity | ≤90%hPa |
Internal insulation | Epoxy resin | Insulation resistance | >500 M Ohms/500Vdc | |
Medium strength | 2500Vac/min | Withstand impulse voltage | 5000V(1.2/50μsStandard Lightning Wave) | |
Operation frequency | 50~400Hz | Accuracy class | According to(IEC 61869-2 or (GB 20840.2-2014)accuracy 0.5,1.0 class | |
Environmental friendly | According to the requirement of RoHS | Certification | According to CE |
Type | L | W | H | H1 | A1 | A2 | A3 | ID | P |
TR0161B | 100 | 28 | 39 | / | / | / | / | 10 | 91 |
TR0159B | 120 | 50 | 56 | / | / | / | / | 20 | 106 |
TR0160B | 158 | 34 | 62 | 4 | 5.2 | 10 | 24 | 20 | 146 |
TR0180B | 196 | 38 | 74 | 5.5 | 6 | 12 | 29 | 30 | 182 |
TR0181B | 196 | 38 | 74 | 5.5 | 6 | 12 | 29 | 35 | 182 |
TR01123B | 50 | 90 | 110 | / | / | / | / | 18 | / |
TR0198-1B | 94 | 53 | 92 | / | / | / | / | 20 | 73 |
TR0199B | 111 | 79.5 | 99 | / | / | / | / | 30 | 90 |
TR01103B | 184 | 65 | 78 | / | / | / | / | 40 | 112 |