TRDP(Ⅲ) Series Rotating Shaft Split-core Current Transformer

It is mainly used for measurement and protection of electrical equipment in 0.66KV AC power system. It can also be used in conjunction with relay protection ,measurement and metering devices and is widely used in urban and rural power grid reconstruction .This type of transformer is easy to install ,does not need to remove the wire once and can also be operated with electricity which does not affect the normal installation and use of customers.
Availability:

*   Rotary shaft opening and closing structure . easy to install and easy to operate .

*   The iron core can be divided ,the precision is high and the magnetic circuit is small.

*   For current measurement ,monitoring and protection of lines and equipment.

*Internal windows are large and can pass through clamps, cables or busbars.


Specification

Parameters

Symbol

Indicator

Rated input current

I n

100A~2000A

Rated output current

I o

1A,5A

Rated load

R L

1VA~20VA

Accuracy class

ρ

0.5,1.0 ,1.5 class

Short-term thermal current

20×In

Withstand voltage

V d

3000Vac/min

Dielectric strength

1000MΩ/500Vac

Operation temperature

Ta

-25℃ ~ +75℃

Environment humidity

≤85%

Operation frequency

f

50~60Hz


Installation Precuations

*  Before installing the open current transformer,it must be connected to the electric meter (or other measuring device )

twice to ensure that the secondary transformer is not open;


*  Place all open current transformers connected with secondary wires on site and wait for installation ;

*  If the primary busbar on site is a cable ,lie installation can be performed; If the primary busbar is a copper bar

,the live operation requires a relatively high level of proficiency for the operator and requires good insulation protection measures ;


*  When installing the transformer ,foreign objects such as impurities and dust should not fall   into the cut surface  of the iron core ,so as not to affect the performance of the transformer.




Type

specification

rated load(VA)

0.5 class

1.0 class

1.5 class

TRDP(III)-30*20

100A/5A

-

-

1.5

150A/5A

-

-

2

200A/5A

-

1.5

2.5

250A/5A

-

1.5

3.75

300A/5A

1.5

3.75

5

400A/5A

2.5

3.75

5

TRDP(III)-60*40

200A/5A

-

1.5

2.5

300A/5A

1.5

2.5

3.75

400A/5A

1.5

2.5

3.75

500A/5A

2.5

5

7.5

600A/5A

2.5

5

7.5

750A/5A

2.5

5

7.5

800A/5A

2.5

5

10

1000A/5A

5

7.5

10

TRDP(III)-80*40

250A/5A

-

1.5

3.75

300A/5A

-

2.5

5

400A/5A

1.5

2.5

5

500A/5A

2.5

5

7.5

600A/5A

2.5

5

7.5

750A/5A

2.5

5

7.5

800A/5A

2.5

5

10

1000A/5A

5

7.5

15

Type

Specification

Rated load(VA)

0.5 class

1.0 class

1.5 class

TRDP(III)-100*40

500A/5A

2.5

5

7.5

600A/5A

2.5

5

7.5

750A/5A

2.5

5

7.5

800A/5A

2.5

7.5

10

1000A/5A

5

7.5

10

1200A/5A

5

7.5

10

1250A/5A

7.5

10

20

1500A/5A

7.5

10

20

TRDP(III)-120*80

500A/5A

2.5

3.75

5

600A/5A

2.5

3.75

5

750A/5A

2.5

5

7.5

800A/5A

5

5

7.5

1000A/5A

5

7.5

10

1200A/5A

7.5

10

15

1250A/5A

10

15

20

1500A/5A

10

15

20

2000A/5A

10

15

20



Product size

Dimensions

Perforation size

W

H

D

A

E

TRDP(III)-30*20

92

103

40

22

32

TRDP(III)-60*40

115

134

36

42


62

TRDP(III)-80*40

113

153

40

42

82

TRDP(III)- 100*40

133

177

40

42

102

TRDP(III)- 120*80

152

197

40

82

122


Installation diagram

Before installing the open current transformer,it must be connected to the electric meter (or other measuring device) twice to ensure that the secondary transformer is not open;

Place all open current transformers connected with secondary wires on site and wait for installation;

If the primary busbar on site is a cable ,lie installation can be performed; If the primary busbar is a copper bar, the live operation requires a relatively high level of proficiency for the operator and the requires good insulation protection measures;

When installing the transformer ,foreign objects such as impurities and dust should not fall into the cut surface of the iron core ,so as not to affect the performance of the transformer.