0-10mA Output Protection Device Zero Sequence Current Transformer

Product Description


Zero Sequence Current Transformer


It can be used for current monitoring and protection in small current grounding systems, fire leakage systems, three-phase current unbalance detection and other equipment.
Main Feature
Enclosed by epoxy resin, good seismic performance
Perforation method, the hole diameter is from φ12mm-φ260mm, which is convenient for busbar installation
High magnetic permeability material with wide measuring range

Electrical Parameter


Primary Input Current :Iin:       0-5A
Secondary Output Current Io:       0-10mA
Nonlinearity:                    Precision 0.2%;
Phase Error15'
Frequency :                     45-1500Hz
Insulation Resistance:             >500mΩ  
Power Frequency Withstand Voltage: >3kV



Product Features

Split-core structure, easy to install on site and easy to operate;

The magnetic core winding structure is cast with epoxy resin, and the end faces of the incision are matched, and the stability is good;

Adopt high-permeability ultra-microcrystalline core, with good linearity and high sensitivity;

Scope of Application

Electrical fire monitoring system, fire-fighting equipment power monitoring system, rural power grid reconstruction project, intelligent power consumption system, low-current grounding system, electromagnetic relay protection, online environmental monitoring, etc.


PERFORMANCE


Electric
Performance
Parameters
Operating Temperature -40℃~+70℃ Relative Humidity ≤90%
Voltage Level 0.4/0.66/0.72KV Linear Range 5%~1000%
Rated Input Current 0~1A Rated Frequency 50/60Hz
Rated Output 0~0.25mA or 0~1V Power Frequency Withstand Voltage 3KV/min
Accuracy Class 0.5、1.0 Insulation Strenth 1000MΩ/500V/min


Mechanical
Structure
Parameters

Shell and Skeleton
PBT/PC Flame Retardant Grade 94-V0
Output Method
Sheathed Lines

Iron Core Material

Nanocrystalline

Split-core Structure
“304”Fastening with inseparable screw
Sealing and Filling Epoxy Resin Construction Plan Base mounting screw fixing






Specification

Shape and Installation Dimensions

Product
Model NO.
Rated
Input
Rated
Output
Precision
Class
Dimensions(mm)
D L W H J K
TRAK-30B




0~1A




0~1A

(0.5mA)




0.5

1.0
30 88 30 68 76 M5
TRAK-45B 45 116 33 86 92 M5
TRAK-65B 65 130 33 105 110 M6
TRAK-80B 80 160 33 128 143 M6
TRAK-100B 100 188 33 154 178 M6
TRAK-150B 150 238 33 204 228 M6

Installation Precautions

The live wire and the neutral wire must pass through the core hole of the transformer at the same time;

Before the iron core is closed, ensure that the end face of the incision is clean, free of stains and impurities;

Use a torque wrench (electric/pneumatic) when tightening the screws, and set the torque to a reasonable range.


Closed loop residual zero sequence current transformer

Residual Zero Sequence Split Core Current Transformer

Electrical Fire Project Usage Zero Phase Split Core Current Transformer

High Sensitivity 0-5A Split Core Current Transformer

Protection Usage Three Phase Balance Monitoring Zero Phase Current Transformer