D Series Split-core Type CT for Outdoor Waterproof, Puncture&Power Harvester and Temperature Measurement

Product characteristic

Open and close structure ,easy to install on site and easy to operate. Quick and easy installation or removal without disconnecting the primary cable under test, effective for safe and easy current testing ;


All manual operation parts are insulators, which can be operated live and can be branched at any position of the cable .


The shell adopts ultrasonic fusion welding integrated molding process, and the magnetic core winding structure is cast with epoxy resin and the waterproof level can be IP66.


Adopt high magnetic ,good linearity and high sensitivity.


Application

Electrical fire monitoring system ,fire equipment power monitoring system ,intelligent power consumption system, intelligent low-voltage power grid, small current grounding system, relay protection ,motor protection system, etc. For current measurement, monitoring and protection of lines and equipment.


Performance


performance
parameters

Operation temperature

-40℃~+70℃

Relative humidity

≤90%

Voltage level

0.4/0.66/0.72KV

Linear range

5%~120%

Rated input current

50~600A

Rated frequency

50/60Hz

Rated load

<20Ω

TemperatureNTC

100K

Accuracy class

0.5级

Dielectric strength

1000MΩ/500V/min

Mechanical
structure
parameters

Shell and skeleton

PA/PCFlammability rating94-V0

Output method

Flexible PVC sheathed wire

Current -output

Green line-black line

Power output

Red line

Temperature measurement output

yellow line –white line

Current output protection

P6KE12CAProtective tube

Core material

Silicon Steel / Nanocrystalline /permalloy

Opening and closing structure

“304”Fastening with inseparable screw

Puncture needle

Stainless steel“304”

Construction plan

Fixing knob to lock the cable


Shape and installation dimensions

Product
model

rated
input

rated
output

accuracy
class

Dimensions(mm)

φ

A

B

C

D

E

BNWAK-36DW

50~600A

0~100mA
or 0~1V

0.5
1.0

35

71

20

34

79

100

BNWSK-36DW

35

71

20

34

79

100

BNWPK-36DW

35

71

20

34

79

100


Output lead description:

1. The input end is a cable through the core (P1 → P2)

2. The output end is led out with a five core shielded wire;

3. Red represents the voltage measurement terminal; Yellow and white are temperature sensors;

4. Green and black represent the secondary current signal output;

5. Define the polarity correspondence between "P1" and the green line as the end with the same name (*)


Installation precautions

When the transformer is powered on ,you must wear insulating gloves and your hands must not directly touch the red core of the shielded wire;

Before the silicon steel core is closed ,ensure that the end face of the incision is clean ,free of stains and impurities; It must be treated with anti-rust agent;

Use a torgue wrench (electric /pneumatic ) when tightening the screws and set the torque to a reasonable range .


Split-core Type Punture&Power Harverster Clamp

LDZKW Series Split-core Type Outdoor Waterproof Current Transformer

F Series Split-core Type Outdoor Waterproof Current Transformer (Round Hanging Wire Type)

D Series Split-core Type CT for Outdoor Waterproof Double Puncture&Power Harvester

C Series Split-core Type Current Transformer (Busbar Perforated with Screw Fixed)