DC Measure Hall Effect Current Transformer

Product Description


FUNCTION :

MEASURE THE ARBIRARY WAVEFORM CURRENT ,SUCH AS DC AC ,TRANSIENT PEAK ,PAMMETERS MEASUREMENT .BETTER LINEARITY ,


GOOD DYNAMIC PERFPRMANCE WORKING HANDWIDE ,STRONG OVERLOAD ABILITY ,


Application :


Used in electric power, industrial automation, machinery, automotive, home appliances and other industries and fields


Brief introduction of principle :


The magnetic field generated by the primary current Ip flowing through the conductor is concentrated in the magnetic ring. The magnitude of this magnetic field is proportional to the current flowing through the conductor. The Hall element in the magnetic ring air gap measures and amplifies the output, and the output voltage Vs is reflecting the primary current Ipo accurately.


Characteristic :


Highly insulated between the primary and secondary side

Small size ,light weight

No insertion loss ,low power consumption

Wide detection range


Technical Parameter

Specification 20A/4V 50A/4V 100A/4V Unit
IPN Primary Rated Input Current 20 50 100 A
IP Primary Current Measurement Range 0~40 0~75 0~150 A
VSN Secondary rated output voltage 4 V
VC The Power Supply Voltage ±12~15(±5%) V
IC Current Consumption <10+Is mA
Vd Insulation Voltage Between primary and secondary circuits:2.5kV/50Hz/1min
εL Linearity <0.2 %FS
X Precision TA=25℃:≤±0.2 %
V0 Offset Voltage TA=25℃:≤±0.1 mV
VOM Magnetic Offset Voltage IP=0 after 3*IPN:≤±0.15 mV
VOT Offset voltage temperature drift IP=0TA=-25~+75℃:≤±0.5 mV/℃
Tr Response time ≤1 μS
f Bandwidth(-3dB) DC~100 kHz
TA Working Temperature -25~+75
TS Storage Temperature -45~+85


Shape and Installation Dimensions

Circuit link diagram

Note:

IPN:Primary current input direction
+ :Positive 12V/15V power supply
G :Power ground
- :Negative 12V/15V power supply
M :Secondary signal output


Installation Precautions

The sensor should be wired correctly, otherwise it may damage the internal components of the sensor

When the sensor is soldered to the circuit board, it needs to be soldered with a low-temperature soldering iron, and the time should not be too long, and secondly, the pins should not be squeezed by a large amount, otherwise the internal connection may be opened.

Dynamic performance (DI/DT and response time) is best when the input current row is fully filled with the primary perforation


Open-loop (Directly Measurement Type) hall Current Sensor

Direct measurement high-precision AC/DC Hall sensor

AC/DC closed-loop (magnetic balance) Hall current sensor

The closed-loop (magnetic balance) Hall current sensor

High-precision AC and DC Hall current sensors