High precision current sensors for measurement TRJC400-26A

Technology Characteristics


Technology Characteristics

◇ Multichannel magnetic compensation feedback  

◇ Tiny misaligned currents          

◇ Superior linearity 

◇ High isolation withstand            

◇ Small error between input & output 

◇ Wide Frequency bandwidth

◇ Fast response speed 

◇ High-resolution

◇ Low temperature drift



Application

◇ New energy detection 

◇ Substitute hall products          

◇ Power electronic measurement 

◇ Industrial control and measurement    

◇ Medical facility 

◇ Standard for laboratory testing

◇ Rail traffic                    

◇ instruments and apparatus


Certificate


◇RoHS/REACH compliant

◇CE certificate

◇UL flame retardant rating 94-V0( For the housing)



Electrical performance


Electrical performance

Type

Symbol

Test condition

Min

Rated

Max

Unit

Measuring range

IPM


--

±400

±480

Adc

Power supply

Vc

Full range

±14.5

±15

±15.5

Vdc

Current consumption

Ic

Within the IPM range

±40

±240

±280

mA

Ratio

KN

Input:Output

2000:1

--

Rated output current

ISN

Primary rated current

--

±200

--

mA

Measuring resistance

RM

Refer to Pic.1

--

5

12

Ω

Precision

Xe

25±10℃

--

--

0.02

%

Linearity

εL

--

--

--

20

ppm

Temperature drift coefficient

TCIOUT

--

--

--

0.1

ppm/K

Zero offset current

Io

25±10℃

--

--

±5

uA

Zero offset current

IoT

Full operating temperature range

--

--

±10

uA

Ripple current

In

DC-10Hz

--

--

2

uA

Dynamic response time

tr

5% up to 90%IPN

--

--

1

us

di/dt accurately followed

di/dt

--

200

--

--

A/us

Frequency bandwidth(- 3 dB)

F

--

0

--

100

kHz

Note: The rated current is rms current when measuring AC

General characteristic

Type

Symbol

Test condition

Min

Nominal

Max

Unit

Operating temperature range

TA

--

-40

--

+85

Storage temperature range

TS

--

-55

--

+100

Output status indication signal

--

When the output status indicator light (green LED) is on, it means that the product works normally, and the input current of the busbar does not exceed its bearing capacity;

When the output status indicator light is off, it indicates that the product is not working properly or the input current value of the busbar is beyond its capacity.


Security feature

Type

Symbol

Test condition

Min

Nominal

Max

Unit

Isolated voltage withstand

Between the primary and secondary

Vd

50Hz,1min

--

2.5

--

KV

Transient isolation withstand voltage

Between the primary and secondary

Vw

50us

--

5

--

KV

This product is molded part, PC material, tolerance of shape and dimensions in accordance with GB/T14486-2008 MT6;

Terminal output type, connected to 2EDGKM3.81-4P terminal.




High-precision AC and DC current sensors TRJC1000-43A

Current Sensors for High-precision Measurement TRJC20-12A

Current sensor for measurement TRJC100-20A

High precision current sensors for measurement TRJC100-20B