Main Characteristics

*   Measures AC, DC and pulsed signals

*   Excellent accuracy, good linearity

*   Strong resistance to external interference, high common mode rejection ratio

*   Low temperature drift, low power consumption, wide frequency band

*   Perforated structure, no insertion loss

Application                      

*   AC frequency conversion speed regulation

*   Servo motor traction

*   Uninterruptible power supply(UPS)

*   Welding machine, battery power supply



Specification

Specification

10A/1V

25A/1V

50A/1V

Unit

IPN

Primary Rated Input

Current

10

25

50

A

IP

Primary Current

Measurement Range

0~20

0~50

0~100

A

VSN

Secondary rated

output voltage

2.5±1

V

VC

The Power Supply

Voltage

+5V(±5%)

V

IC

Current Consumption

<20

mA

Vd

Insulation Voltage

Between primary and secondary circuits:3kV/50Hz/1min


εL

Linearity

<0.1

%FS

X

Precision

T A=25℃:≤±0.5

%

V0

Offset Voltage

T A=25℃:≤±10

mV

VOM

Magnetic Offset

Voltage

I P =0 after 3*IPN:≤±10

mV

VOT

Offset voltage

temperature drift

I P =0 TA=-40~+80℃:≤±0.1

mV/℃

Tr

Response time

<1

μS

f

Bandwidth(-1dB )

DC~200

kHz

TA

Working Temperature

-40~+80

TS

Storage Temperature

-45~+85


Structure and Dimension

Circuit link diagram

Note:

IPN:Primary current input direction

+ :Positive 5V power supply G :Power ground

M :Secondary signal output R :Reference voltage


Installation Precaution

*    The sensor should be wired correctly, otherwise it may damage the internal components of the sensor

*    When the sensor is soldered to the circuit board, it needs to be

soldered with a low-temperature soldering iron, and the time should not be too long, and secondly, the pins should not be squeezed by a large amount, otherwise the internal connection may be opened.