A Series Split-core Cable Type Current Transformer

Product Features

* The buckle structure is fixed and the stability is good;

* According to the cable specifications used in the main circuit, there are various core hole diameters

to it ;

* Wide quantity limit and strong anti-saturation ability .Rated primary current range :1~1000A,rated secondary

current range :0~5 A, current transformation ratio range can reach 100:1~10000:1;

* Provide a variety of combined output methods: when outputting ampere-level current, you can use PVC
wire terminals alone ,output Ma-level current, you can choose three-phrase integrated collection terminals and

choose a variety of signal interfaces.
*Adopt high magnetic permeability core, good linearity and high sensitively .


Application

Rural power grid reconstruction project, online environmental monitoring ,smart fire-fighting power consumption, low-voltage power distribution system, smart power consumption system, electricity measurement ,power quality analysis and electrical equipment signal collection ,lighting equipment such as power installations, small current grounding systems, etc.


Product Parameters


Electrical performance

Operation temperature

-40°C~+70°C

Relative humidity

≤90%

Voltage level

0.4/0.66/0.72KV

Linear range

5%~120%

Rated input current

0~1500A

Rated frequency

50/60Hz

Rated capacity

0~5VA

Power frequency withstand voltage

3KV/min

Accuracy class

0.5、1.0

Dielectric strength

1000MΩ/500V/min

Mechanical structure

Shell

PA/PC Flammability rating 94-V0

Output method

PVC Sheathed cable/RJ12 Crystal terminal /PS/2Round head male interface

Winding bobbin

PBT

Opening-closing structure

snap

Core material

Silicon steel/manganese zinc ferrite

Construction plan

Nylon cable ties bundled and fixed cables



Model Definition


Typical Value and Dimension

Product model

rated input

rated output

accuracy class

Dimensions(mm)

D

L

W

H

TRFK-10A

0~75A

0~50mA(0~1.0V)

0.2 0.3 0.5 0.5s

9

34.5

37.5

45

TRFK-16A

0~150A

0~100mA(0~2.5V)

15

40.5

42.5

52

TRFK-24A

0~250A

0~100mA(0~5.0V)

22.5

54

47

71

TRSK-36-1A

0~300A

0~100mA(0~7.0V)

35

61

53

81

TRSK-36A

0~500A

0~100mA(0~7.0V)

35

66

53

87

TRSK-50-1A

0~600A

0~100mA(0~7.0V)

49

81

59

107.5

TRSK-50A

0~800A

0~100mA(0~7.0V)

50

88

59

114

TRSK-10A

5~100A

0~200mA(0.5VA)

0.5 0.5s 1 3

9

34.5

37.5

45

TRFK-16A

5~150A

0~1A(0.5VA 1VA)

15

40.5

42.5

52

TRFK-24A

10~300A

0~5A(0.5VA 2.5VA)

22.5

54

47

71

TRSK-36-1A

10~500A

0~5A(0.5VA 2.5VA)

35

61

53

81

TRSK-36A

10~600A

0~5A(0.5VA 3.75VA)

35

66

53

87

TRSK-50-1A

10~1000A

0~5A(0.5VA 3.75VA)

49

81

59

107.5

TRSK-50A

10~1500A

0~5A(0.5VA 5VA)

50

88

59

114


Typical Value and Dimension

Split-core Type Punture&Power Harverster Clamp

LDZKW Series Split-core Type Outdoor Waterproof Current Transformer

F Series Split-core Type Outdoor Waterproof Current Transformer (Round Hanging Wire Type)

D Series Split-core Type CT for Outdoor Waterproof Double Puncture&Power Harvester

D Series Split-core Type CT for Outdoor Waterproof, Puncture&Power Harvester and Temperature Measurement